Seria HES - energooszczędne osuszacze ziębnicze powietrza 2500-3000 scfm
OSUSZACZE SPRĘŻONEGO POWIETRZA / ZIĘBNICZE OSUSZACZE SPRĘŻONEGO POWIETRZA
Seria HES zmniejsza zużycie energii dzięki innowacyjnej technologii - jest to najlepsze rozwiązanie dla profili zapotrzebowania na powietrze o dużym obciążeniu.
Share
Digital Evaporator Technology continues the Hankison tradition of stable 38°F (3°C) dew points. The HES Series, offers energy saving advantages over traditional non-cycling, cycling and variable speed designs. Hankison technology platforms of heat exchangers, filtration and refrigeration are CSA and UL certified.
Rapid Return-On-Investment (ROI)
The HES Series is designed to provide a rapid return on investment by:
- Reducing the dryer's energy consumption down to 9% (91% savings) at 0% load
- Precise matching of average air flow (heat load) with the required input kW power
- Qualifying for energy rebates offered by utility companies
- Maintaining a stable 38°F (3°C) dew point with no dew point spikes
Hankison crafts quality refrigerated dryers engineered to match the specific air demands of your compressed air system.
MODEL | Rated Flow 1 | Voltages 2 | Power 3 | Inlet/Outlet Connections 4 | |
---|---|---|---|---|---|
scfm | nm3/h | V/ph/Hz | kW | ||
HES2500 | 2500 | 4248 | Standard: 380-420/3/50 460/3/60 Optional: 230/3/60 575/3/60 | 16.80 | 6” FLG |
HES3000 | 3000 | 5097 | 18.20 | 6” FLG |
Dryers meet agency approvals: CSA (CAN /CSA-C22.2 No.236-05) - Heating and Cooling Equipment and U L Standard No.1995.
Canadian Registration Numbers- standard separator vessel and optional cold coalescing vessel.
1 Dryer flow ratings are in accordance with ISO 7183 (option A2) conditions: inlet air at 100 psig (7 barg) and 100°F (38°C) saturated, ambient air at 100°F (38°C), operating on 60 Hz power supply.
2 Optional Voltages: 575/3/60 models utilize mounted transformers to step-down incoming power to 460/3/60; 230/3/60 models utilize mounted transformers to step-up to 460/3/60.
3 Full flow kW value operating on 460/3/60 Hz power supply.
4 DIN Flanges available.
Maximum Working Pressure | Minimum Working Pressure | Maximum Inlet Air Temperature | Minimum Inlet Air Temperature | Maximum Ambient Air Temperature | Minimum Ambient Air Temperature | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
psig | barg | psig | barg | °F | °C | °F | °C | °F | °C | °F | °C |
232 | 16 | 30 | 2 | 130 | 54 | 40 | 4 | 110 | 43 | 40 | 4 |
MODEL | DIMENSIONS (INCHES) | WEIGHT LBS | ||
---|---|---|---|---|
H | W | D | ||
HES2500 | 85 | 55 | 60 | 2,315 |
MODEL | DIMENSIONS (INCHES) | WEIGHT LBS | ||
---|---|---|---|---|
H | W | D | ||
HES3000 | 85 | 55 | 60 | 2,646 |
HES2500
MODEL | DIMENSIONS (INCHES) | WEIGHT LBS | ||
---|---|---|---|---|
H | W | D | ||
HES2500 | 85 | 55 | 60 | 2,315 |
HES3000
MODEL | DIMENSIONS (INCHES) | WEIGHT LBS | ||
---|---|---|---|---|
H | W | D | ||
HES3000 | 85 | 55 | 60 | 2,646 |
Features
Digital Evaporator Technology continues the Hankison tradition of stable 38°F (3°C) dew points. The HES Series, offers energy saving advantages over traditional non-cycling, cycling and variable speed designs. Hankison technology platforms of heat exchangers, filtration and refrigeration are CSA and UL certified.
Rapid Return-On-Investment (ROI)
The HES Series is designed to provide a rapid return on investment by:
- Reducing the dryer's energy consumption down to 9% (91% savings) at 0% load
- Precise matching of average air flow (heat load) with the required input kW power
- Qualifying for energy rebates offered by utility companies
- Maintaining a stable 38°F (3°C) dew point with no dew point spikes
Hankison crafts quality refrigerated dryers engineered to match the specific air demands of your compressed air system.
Specifications
MODEL | Rated Flow 1 | Voltages 2 | Power 3 | Inlet/Outlet Connections 4 | |
---|---|---|---|---|---|
scfm | nm3/h | V/ph/Hz | kW | ||
HES2500 | 2500 | 4248 | Standard: 380-420/3/50 460/3/60 Optional: 230/3/60 575/3/60 | 16.80 | 6” FLG |
HES3000 | 3000 | 5097 | 18.20 | 6” FLG |
Dryers meet agency approvals: CSA (CAN /CSA-C22.2 No.236-05) - Heating and Cooling Equipment and U L Standard No.1995.
Canadian Registration Numbers- standard separator vessel and optional cold coalescing vessel.
1 Dryer flow ratings are in accordance with ISO 7183 (option A2) conditions: inlet air at 100 psig (7 barg) and 100°F (38°C) saturated, ambient air at 100°F (38°C), operating on 60 Hz power supply.
2 Optional Voltages: 575/3/60 models utilize mounted transformers to step-down incoming power to 460/3/60; 230/3/60 models utilize mounted transformers to step-up to 460/3/60.
3 Full flow kW value operating on 460/3/60 Hz power supply.
4 DIN Flanges available.
Maximum Working Pressure | Minimum Working Pressure | Maximum Inlet Air Temperature | Minimum Inlet Air Temperature | Maximum Ambient Air Temperature | Minimum Ambient Air Temperature | ||||||
---|---|---|---|---|---|---|---|---|---|---|---|
psig | barg | psig | barg | °F | °C | °F | °C | °F | °C | °F | °C |
232 | 16 | 30 | 2 | 130 | 54 | 40 | 4 | 110 | 43 | 40 | 4 |
Dimensions
MODEL | DIMENSIONS (INCHES) | WEIGHT LBS | ||
---|---|---|---|---|
H | W | D | ||
HES2500 | 85 | 55 | 60 | 2,315 |
MODEL | DIMENSIONS (INCHES) | WEIGHT LBS | ||
---|---|---|---|---|
H | W | D | ||
HES3000 | 85 | 55 | 60 | 2,646 |
HES2500
MODEL | DIMENSIONS (INCHES) | WEIGHT LBS | ||
---|---|---|---|---|
H | W | D | ||
HES2500 | 85 | 55 | 60 | 2,315 |
HES3000
MODEL | DIMENSIONS (INCHES) | WEIGHT LBS | ||
---|---|---|---|---|
H | W | D | ||
HES3000 | 85 | 55 | 60 | 2,646 |