HHL Heatless Regenerative Desiccant Dryers
Desiccant compressed air dryer
Air flow rates 90m³/h to 9000 m³/h
Utilizing twin towers filled with premium grade activated alumina, Hankison Heatless dryers are available with different application-specific control systems to meet the needs of the industry with economy and performance.
Share
Utilizing twin towers filled with premium grade activated alumina, Hankison Heatless dryers are available with different application-specific control systems to meet the needs of the industry with economy and performance. Â
HHL Series heatless desiccant dryers provide consistent outlet pressure dew points to -70°C.Â
Standard InstrumentationÂ
- Left and right tower pressure gaugesÂ
- Purge pressure gaugeÂ
- Moisture indicator - alerts operator of elevated dew pointÂ
- The throttling valve provides accurate purge pressure adjustment.Â
- With inlet and outlet filters as standard Â
- HHL 91 – HHL 901 standard up to 16 barÂ
- HHL 1051 – HHL 9001 standard 10 bar (g) 16 bar on request  Â
Controller OptionsÂ
Level 1Â
Pure and SimpleÂ
HHL Series presents traditional heatless drying technology. Using a simple timer-based controller, these are designed to deliver maximum value to applications that operate at or near full capacity. Automatic time-controlled bed regeneration cycles offer consistent performance and economy of purchase.Â
LX ControllerÂ
It is a Standard SPS Controller with a PDP Sensor and an Energy Saving feature
Specificaions
Model | Flow Rate* | Connection | Power Supply | Dimensions (mm) | Weight | Recommended filtration | |||
 | (m³/h) |  | (V/ph/Hz) | Width | Depth | Height | (kg) | Pre-filter | Post-filter |
HHL 91 | 90 | R 3/4" | 95-240/1/50 95/240/1/60 | 750 | 750 | 1950 | 181 | F06-B-HF | F06-B-PF |
HHL 141 | 140 | R 3/4" | 750 | 750 | 1950 | 220 | F07-B-HF | F07-B-PF | |
HHL 271 | 270 | R1" | 1150 | 750 | 1980 | 398 | F08-B-HF | F08-B-PF | |
HHL 351 | 350 | R1 1/2" | 1150 | 750 | 1980 | 421 | FIO-B-HF | FIO-B-PF | |
HHL 521 | 520 | R1 1/2" | 1150 | 750 | 1990 | 531 | F11-B-HF | F11-B-PF | |
HHL 681 | 680 | R11/2" | 1150 | 750 | 1990 | 650 | F12-B-HF | F12-B-PF | |
HHL 901 | 900 | R2" | 1150 | 849 | 2000 | 815 | F14-B-HF | F14-B-PF | |
HHL 1051 | 1050 | R2 1/2" | 95-240/1/50 95/240/1/60 | 1500 | 1320 | 2011 | 965 | F14-B-HE | F14-B-PF |
HHL 1351 | 1350 | R2 1/2" | 1500 | 1420 | 1995 | 1275 | F15-B-HF | F15-B-PF | |
HHL 1651 | 1650 | R 3" | 1500 | 1470 | 2147 | 1525 | F16-B-HF | F16-B-PF | |
HHL 1951 | 1950 | R3" | 1500 | 1520 | 2175 | 1710 | F17-B-HF | F17-B-PF | |
HHL 2351 | 2350 | DN 100 | 1500 | 1720 | 2193 | 2080 | HF5-60 | HF6-60 | |
HHL 2701 | 2700 | DN 100 | 1700 | 1770 | 2210 | 2305 | HF5-60 | HF6-60 | |
HHL 3601 | 3600 | DN 100 | 1950 | 1920 | 2200 | 2755 | HF5-64 | HF6-64 | |
HHL 5201 | 5200 | DN 150 | 2400 | 2164 | 2390 | 4105 | HF5-68 | HF6-68 | |
HHL 7101 | 7100 | DN 150 | 2690 | 2334 | 2709 | 6200 | HF5-72 | HF6-72 | |
HHL 9001 | 9000 | DN 150 | 2820 | 2594 | 2568 | 6800 | HF5-76 | HF6-76 |
Â
MODELÂ | DIMENSIONS (INCHES) | WEIGHT | |||||
---|---|---|---|---|---|---|---|
H | W | D | |||||
IN | Â mm | IN | Â mm | IN | Â mm | LBS | |
HHS/HHL/HHE-40 | 46 | 1,168 | 32 | 813 | 32 | 813 | 365 |
Features
Utilizing twin towers filled with premium grade activated alumina, Hankison Heatless dryers are available with different application-specific control systems to meet the needs of the industry with economy and performance. Â
HHL Series heatless desiccant dryers provide consistent outlet pressure dew points to -70°C.Â
Standard InstrumentationÂ
- Left and right tower pressure gaugesÂ
- Purge pressure gaugeÂ
- Moisture indicator - alerts operator of elevated dew pointÂ
- The throttling valve provides accurate purge pressure adjustment.Â
- With inlet and outlet filters as standard Â
- HHL 91 – HHL 901 standard up to 16 barÂ
- HHL 1051 – HHL 9001 standard 10 bar (g) 16 bar on request  Â
Controller OptionsÂ
Level 1Â
Pure and SimpleÂ
HHL Series presents traditional heatless drying technology. Using a simple timer-based controller, these are designed to deliver maximum value to applications that operate at or near full capacity. Automatic time-controlled bed regeneration cycles offer consistent performance and economy of purchase.Â
LX ControllerÂ
It is a Standard SPS Controller with a PDP Sensor and an Energy Saving feature
Specifications
Specificaions
Model | Flow Rate* | Connection | Power Supply | Dimensions (mm) | Weight | Recommended filtration | |||
 | (m³/h) |  | (V/ph/Hz) | Width | Depth | Height | (kg) | Pre-filter | Post-filter |
HHL 91 | 90 | R 3/4" | 95-240/1/50 95/240/1/60 | 750 | 750 | 1950 | 181 | F06-B-HF | F06-B-PF |
HHL 141 | 140 | R 3/4" | 750 | 750 | 1950 | 220 | F07-B-HF | F07-B-PF | |
HHL 271 | 270 | R1" | 1150 | 750 | 1980 | 398 | F08-B-HF | F08-B-PF | |
HHL 351 | 350 | R1 1/2" | 1150 | 750 | 1980 | 421 | FIO-B-HF | FIO-B-PF | |
HHL 521 | 520 | R1 1/2" | 1150 | 750 | 1990 | 531 | F11-B-HF | F11-B-PF | |
HHL 681 | 680 | R11/2" | 1150 | 750 | 1990 | 650 | F12-B-HF | F12-B-PF | |
HHL 901 | 900 | R2" | 1150 | 849 | 2000 | 815 | F14-B-HF | F14-B-PF | |
HHL 1051 | 1050 | R2 1/2" | 95-240/1/50 95/240/1/60 | 1500 | 1320 | 2011 | 965 | F14-B-HE | F14-B-PF |
HHL 1351 | 1350 | R2 1/2" | 1500 | 1420 | 1995 | 1275 | F15-B-HF | F15-B-PF | |
HHL 1651 | 1650 | R 3" | 1500 | 1470 | 2147 | 1525 | F16-B-HF | F16-B-PF | |
HHL 1951 | 1950 | R3" | 1500 | 1520 | 2175 | 1710 | F17-B-HF | F17-B-PF | |
HHL 2351 | 2350 | DN 100 | 1500 | 1720 | 2193 | 2080 | HF5-60 | HF6-60 | |
HHL 2701 | 2700 | DN 100 | 1700 | 1770 | 2210 | 2305 | HF5-60 | HF6-60 | |
HHL 3601 | 3600 | DN 100 | 1950 | 1920 | 2200 | 2755 | HF5-64 | HF6-64 | |
HHL 5201 | 5200 | DN 150 | 2400 | 2164 | 2390 | 4105 | HF5-68 | HF6-68 | |
HHL 7101 | 7100 | DN 150 | 2690 | 2334 | 2709 | 6200 | HF5-72 | HF6-72 | |
HHL 9001 | 9000 | DN 150 | 2820 | 2594 | 2568 | 6800 | HF5-76 | HF6-76 |
Dimensions
Â
MODELÂ | DIMENSIONS (INCHES) | WEIGHT | |||||
---|---|---|---|---|---|---|---|
H | W | D | |||||
IN | Â mm | IN | Â mm | IN | Â mm | LBS | |
HHS/HHL/HHE-40 | 46 | 1,168 | 32 | 813 | 32 | 813 | 365 |