NGF Series - Compressed Air Filters

Air flow rates 34m³/h to 2549m³/h

As energy costs continue to escalate globally air treatment manufacturers are challenged to design equipment that is cost-effective, delivers optimum performance, and consumes less energy.

Besides our NGF series, we have High pressure (HP) and High Temperature (HTA) filters in the flow range of 105m³/h to 2200m³/h. 

Hankison's Next Generation Filter Series is the solution for efficiently removing contamination from compressed air systems while saving energy. The NGF Series employs technological advancements in filtration materials and design to ensure premium compressed air quality and low operational costs. Every filter is tested and rated delivering certifiable performance according to ISO 8573-1 air quality standards.

The NGF Series is also tested to ISO 12500. Test results provide certifiable performance data based on defined challenge concentrations. A choice of Five Element Grades allows you to design a system that delivers the air quality you require:

  • Grade SF - Bulk Liquid Separator/Filter Grade PF - General Purpose Filter Grade
  • HF - High Efficiency Oil Removal Filter Grade 
  • UF - Ultra High-Efficiency Oil Removal Filter Grade
  • CF - Oil Vapor Removal Filter

NGF Series filters feature:

  1. Patented Venturi-Wave™ element design promotes a turbulent-free transition for compressed air entering the element
  2. Deep bed pleated, high performance media
  3. Element grade identification with color-coded end caps printed with genuine Hankison filter element replacement part number
  4. Sculpted housing design with flanged inlet and outlet connections for easy installation
  5. Die-cast aluminum, chromated housings are coated with a polyester epoxy powder coat finish for corrosion resistance. The Internally ribbed bowl promotes condensate drainage
ModelCapacity @ 100 psig
(6.7 barg)
Inlet/Outlet
Connections
scfmnm3/hin.
F02 -20341/4” NPT
F03 -35693/8” NPT
F04 -50 851/2” NPT
F067.51273/4” NPT
F071031753/4” NPT
F081572671” NPT
F102574371 1/2” NPT
F113606121 1/2” NPT
F124016812” NPT
F135689652 1/2” NPT
F1477513172 1/2” NPT
F15120020392 1/2” NPT
F16120020393” NPT
F17150025493” NPT

Pressure Drop Performance

MODELFilter DescriptionDry △pWetted△p
psigbargpsigbarg
SFBulk Liquid Separator/0.80.06100.07
PFGeneral Purpose Filter0.60.041.40.10
HFHigh Efficiency Oil Removal Filter0.60.041.80.12
UFUltra High Efficiency Oil Removal Filter0.80.06 -200.14
CFOil Vapor Removal Filter100.07--

NGF Series Filtration Performance

ElementSFPFHFUFCF
Particle Retention Size1
(Per ISO 12500-3)
3.0 µm1.0 µm0.01 µm0.01 µm0.01 µm
Particle Removal Efficiency
(Per ISO 12500-3)
-99.999+%99.999+%99.999+%99.999+%
Oil Removal Efficiency
(Per ISO 12500-1)
 -5080%99.9+%99.9+%-
Remaining Oil Content2 (Per ISO 12500-1)5.0 mg/m32.0 mg/m3< 0.01 mg/m3< 0.001 mg/m3< 0.004 mg/m3
(as a vapor)

1 Solid particulate size distribution 0.01 to 5.0 µm
2 Inlet oil challenge concentration 10 mg/m3

Features

Hankison's Next Generation Filter Series is the solution for efficiently removing contamination from compressed air systems while saving energy. The NGF Series employs technological advancements in filtration materials and design to ensure premium compressed air quality and low operational costs. Every filter is tested and rated delivering certifiable performance according to ISO 8573-1 air quality standards.

The NGF Series is also tested to ISO 12500. Test results provide certifiable performance data based on defined challenge concentrations. A choice of Five Element Grades allows you to design a system that delivers the air quality you require:

  • Grade SF - Bulk Liquid Separator/Filter Grade PF - General Purpose Filter Grade
  • HF - High Efficiency Oil Removal Filter Grade 
  • UF - Ultra High-Efficiency Oil Removal Filter Grade
  • CF - Oil Vapor Removal Filter

NGF Series filters feature:

  1. Patented Venturi-Wave™ element design promotes a turbulent-free transition for compressed air entering the element
  2. Deep bed pleated, high performance media
  3. Element grade identification with color-coded end caps printed with genuine Hankison filter element replacement part number
  4. Sculpted housing design with flanged inlet and outlet connections for easy installation
  5. Die-cast aluminum, chromated housings are coated with a polyester epoxy powder coat finish for corrosion resistance. The Internally ribbed bowl promotes condensate drainage

Specifications

ModelCapacity @ 100 psig
(6.7 barg)
Inlet/Outlet
Connections
scfmnm3/hin.
F02 -20341/4” NPT
F03 -35693/8” NPT
F04 -50 851/2” NPT
F067.51273/4” NPT
F071031753/4” NPT
F081572671” NPT
F102574371 1/2” NPT
F113606121 1/2” NPT
F124016812” NPT
F135689652 1/2” NPT
F1477513172 1/2” NPT
F15120020392 1/2” NPT
F16120020393” NPT
F17150025493” NPT

Performance

Pressure Drop Performance

MODELFilter DescriptionDry △pWetted△p
psigbargpsigbarg
SFBulk Liquid Separator/0.80.06100.07
PFGeneral Purpose Filter0.60.041.40.10
HFHigh Efficiency Oil Removal Filter0.60.041.80.12
UFUltra High Efficiency Oil Removal Filter0.80.06 -200.14
CFOil Vapor Removal Filter100.07--

NGF Series Filtration Performance

ElementSFPFHFUFCF
Particle Retention Size1
(Per ISO 12500-3)
3.0 µm1.0 µm0.01 µm0.01 µm0.01 µm
Particle Removal Efficiency
(Per ISO 12500-3)
-99.999+%99.999+%99.999+%99.999+%
Oil Removal Efficiency
(Per ISO 12500-1)
 -5080%99.9+%99.9+%-
Remaining Oil Content2 (Per ISO 12500-1)5.0 mg/m32.0 mg/m3< 0.01 mg/m3< 0.001 mg/m3< 0.004 mg/m3
(as a vapor)

1 Solid particulate size distribution 0.01 to 5.0 µm
2 Inlet oil challenge concentration 10 mg/m3