HHL Heatless Regenerative Desiccant Dryers
Desiccant compressed air dryer
Air flow rates 90m³/h to 9000 m³/h
Utilizing twin towers filled with premium grade activated alumina, Hankison Heatless dryers are available with different application-specific control systems to meet the needs of the industry with economy and performance.
Share
Utilizing twin towers filled with premium grade activated alumina, Hankison Heatless dryers are available with different application-specific control systems to meet the needs of the industry with economy and performance.
HHL Series heatless desiccant dryers provide consistent outlet pressure dew points to -70°C.
Standard Instrumentation
- Left and right tower pressure gauges
- Purge pressure gauge
- Moisture indicator - alerts operator of elevated dew point
- The throttling valve provides accurate purge pressure adjustment.
- With inlet and outlet filters as standard
- HHL 91 – HHL 901 standard up to 16 bar
- HHL 1051 – HHL 9001 standard 10 bar (g) 16 bar on request
Controller Options
Level 1
Pure and Simple
HHL Series presents traditional heatless drying technology. Using a simple timer-based controller, these are designed to deliver maximum value to applications that operate at or near full capacity. Automatic time-controlled bed regeneration cycles offer consistent performance and economy of purchase.
LX Controller
It is a Standard SPS Controller with a PDP Sensor and an Energy Saving feature
Specificaions
MODEL | INLET FLOW @ 100 PSI (6.7 BAR) | INLET/OUTLET CONNECTIONS | |
---|---|---|---|
SCFM | NM3/H | IN | |
HHS/HHL/HHE-40 | 40 | 68 | 1" NPT |
HHS/HHL/HHE-60 | 60 | 102 | 1" NPT |
HHS/HHL/HHE-90 | 90 | 153 | 1" NPT |
HHS/HHL/HHE-115 | 115 | 195 | 1" NPT |
HHS/HHL/HHE-165 | 165 | 280 | 1" NPT |
HHS/HHL/HHE-260 | 260 | 442 | 2" NPT |
HHS/HHL/HHE-370 | 370 | 629 | 2" NPT |
HHS/HHL/HHE-450 | 450 | 765 | 2" NPT |
HHS/HHL/HHE-590 | 590 | 1,002 | 2" NPT |
HHS/HHL/HHE-750 | 750 | 1,274 | 3” ANSI FLG. |
HHS/HHL/HHE-930 | 930 | 1,580 | 3” ANSI FLG. |
HHS/HHL/HHE-1130 | 1,130 | 1,920 | 3” ANSI FLG. |
HHS/HHL/HHE-1350 | 1,350 | 2,294 | 3” ANSI FLG. |
HHS/HHL/HHE-1550 | 1,550 | 2,634 | 3” ANSI FLG. |
HHS/HHL/HHE-2100 | 2,100 | 3,568 | 4” ANSI FLG. |
HHS/HHL/HHE-3000 | 3,000 | 5,097 | 4” ANSI FLG. |
HHS/HHL/HHE-4100 2 | 4,100 | 6,966 | 6” ANSI FLG |
HHS/HHL/HHE-5400 2 | 5,400 | 9,175 | 6” ANSI FLG |
Maximum Working Pressure: 150 psi (10.5 bar) standard, 250 psi (17.6 bar) optional. Units with higher Maximum Working Pressures are available.
Minimum Operating Pressure: 150 psi (10.5 bar) units - 60 psi (4.2 bar), 250 psi (17.6 bar) - 120 psi (8.4 bar)
Maximum Inlet Air or Ambient Air Temperature: 120ºF (49ºC)
Pressure Drop at Rated Flow: Less than 5 psi (0.35 bar)
Available Voltages: HHE - 100-120V/1ph/50-60Hz, HHL/HHS - 100-240V/1ph/50-60Hz and 12-24 VDC, NEMA 4 Standard Pressure Drop at Rated Flow: Less than 5
psi (0.35 bar) Dimensions and weights are for reference only. Request certified drawings for construction purposes.
1 BSP and DIN flanges available 2 Supplied with Premium Quality Butterfly Switching Valves
MODEL | DIMENSIONS (INCHES) | WEIGHT | |||||
---|---|---|---|---|---|---|---|
H | W | D | |||||
IN | mm | IN | mm | IN | mm | LBS | |
HHS/HHL/HHE-40 | 46 | 1,168 | 32 | 813 | 32 | 813 | 365 |
Features
Utilizing twin towers filled with premium grade activated alumina, Hankison Heatless dryers are available with different application-specific control systems to meet the needs of the industry with economy and performance.
HHL Series heatless desiccant dryers provide consistent outlet pressure dew points to -70°C.
Standard Instrumentation
- Left and right tower pressure gauges
- Purge pressure gauge
- Moisture indicator - alerts operator of elevated dew point
- The throttling valve provides accurate purge pressure adjustment.
- With inlet and outlet filters as standard
- HHL 91 – HHL 901 standard up to 16 bar
- HHL 1051 – HHL 9001 standard 10 bar (g) 16 bar on request
Controller Options
Level 1
Pure and Simple
HHL Series presents traditional heatless drying technology. Using a simple timer-based controller, these are designed to deliver maximum value to applications that operate at or near full capacity. Automatic time-controlled bed regeneration cycles offer consistent performance and economy of purchase.
LX Controller
It is a Standard SPS Controller with a PDP Sensor and an Energy Saving feature
Specifications
Specificaions
MODEL | INLET FLOW @ 100 PSI (6.7 BAR) | INLET/OUTLET CONNECTIONS | |
---|---|---|---|
SCFM | NM3/H | IN | |
HHS/HHL/HHE-40 | 40 | 68 | 1" NPT |
HHS/HHL/HHE-60 | 60 | 102 | 1" NPT |
HHS/HHL/HHE-90 | 90 | 153 | 1" NPT |
HHS/HHL/HHE-115 | 115 | 195 | 1" NPT |
HHS/HHL/HHE-165 | 165 | 280 | 1" NPT |
HHS/HHL/HHE-260 | 260 | 442 | 2" NPT |
HHS/HHL/HHE-370 | 370 | 629 | 2" NPT |
HHS/HHL/HHE-450 | 450 | 765 | 2" NPT |
HHS/HHL/HHE-590 | 590 | 1,002 | 2" NPT |
HHS/HHL/HHE-750 | 750 | 1,274 | 3” ANSI FLG. |
HHS/HHL/HHE-930 | 930 | 1,580 | 3” ANSI FLG. |
HHS/HHL/HHE-1130 | 1,130 | 1,920 | 3” ANSI FLG. |
HHS/HHL/HHE-1350 | 1,350 | 2,294 | 3” ANSI FLG. |
HHS/HHL/HHE-1550 | 1,550 | 2,634 | 3” ANSI FLG. |
HHS/HHL/HHE-2100 | 2,100 | 3,568 | 4” ANSI FLG. |
HHS/HHL/HHE-3000 | 3,000 | 5,097 | 4” ANSI FLG. |
HHS/HHL/HHE-4100 2 | 4,100 | 6,966 | 6” ANSI FLG |
HHS/HHL/HHE-5400 2 | 5,400 | 9,175 | 6” ANSI FLG |
Maximum Working Pressure: 150 psi (10.5 bar) standard, 250 psi (17.6 bar) optional. Units with higher Maximum Working Pressures are available.
Minimum Operating Pressure: 150 psi (10.5 bar) units - 60 psi (4.2 bar), 250 psi (17.6 bar) - 120 psi (8.4 bar)
Maximum Inlet Air or Ambient Air Temperature: 120ºF (49ºC)
Pressure Drop at Rated Flow: Less than 5 psi (0.35 bar)
Available Voltages: HHE - 100-120V/1ph/50-60Hz, HHL/HHS - 100-240V/1ph/50-60Hz and 12-24 VDC, NEMA 4 Standard Pressure Drop at Rated Flow: Less than 5
psi (0.35 bar) Dimensions and weights are for reference only. Request certified drawings for construction purposes.
1 BSP and DIN flanges available 2 Supplied with Premium Quality Butterfly Switching Valves
Dimensions
MODEL | DIMENSIONS (INCHES) | WEIGHT | |||||
---|---|---|---|---|---|---|---|
H | W | D | |||||
IN | mm | IN | mm | IN | mm | LBS | |
HHS/HHL/HHE-40 | 46 | 1,168 | 32 | 813 | 32 | 813 | 365 |